Anti-Mullerian Hormone (AMH) Antibody Pair
如果您對該產(chǎn)品感興趣的話,可以
產(chǎn)品名稱: Anti-Mullerian Hormone (AMH) Antibody Pair
產(chǎn)品型號: abx370826
產(chǎn)品展商: 其他品牌
產(chǎn)品文檔: 無相關(guān)文檔
簡單介紹
Anti-Mullerian Hormone (AMH) Antibody Pair
Anti-Mullerian Hormone (AMH) Antibody Pair
的詳細介紹
Anti-Mullerian Hormone (AMH) Antibody Pair for use in Competitive ELISA assay development. The 10 × 96 tests size contains:
- 32 μg Anti-Mullerian Hormone (AMH) rabbit polyclonal capture antibody,
- 32 μg Anti-Mullerian Hormone (AMH) biotin-conjugated competitor (AMH-BSA coupling complex),
- 300 ng Anti-Mullerian Hormone (AMH) standard.
It is recommended to use this antibody pair with abx098959 Antibody Pair Support Kit (Competitive Method).
Target |
Anti-Mullerian Hormone (AMH) |
Reactivity |
Human |
Tested Applications |
ELISA |
Recommended dilutions |
Dilute the Capture Antibody 1111-fold with Coating Buffer. Dilute the biotin-conjugated Competitor 1430-fold with Biotin-Conjugated Competitor Diluent. Optimal dilutions/concentrations should be determined by the end user. |
Form |
Liquid (Capture Antibody and Detection Antibody) |
Reconstitution |
Reconstitute the standard with Standard Diluent. The volume, and therefore standard concentration, should be determined by the end user. |
Test Range |
185.2 pg/ml - 15000 pg/ml |
Storage |
Store at 2 to 8 °C for up to one month. Aliquot and store at -80 °C for up to one year. Avoid repeated freeze/thaw cycles. All solutions should be made fresh before the experiment. |
Concentration |
32 μg/0.09 ml (Capture Antibody), 32 μg/0.07 ml (Biotin-Conjugated Competitor) |
Standard Form |
Lyophilized |
ELISA Type |
Competitive |
Capture Antibody Conjugation |
Unconjugated |
Detection Antibody Conjugation |
Biotin |
Buffer |
The capture and detection antibody both contain 0.1% sodium azide. |
Directions for use |
Bring all components to room temperature (18-25°C) and briefly spin or centrifuge the vials before use. Working solutions should be prepared and used immediately.
Recommended Procedure: - Dilute the Capture Antibody to working concentration using Coating Buffer. Immediately coat the 96-well plate with diluted Capture Antibody (100 μl per well). Seal the plate and incubate at 4 °C overnight or at 37 °C for 2 hours
- Aspirate the wells and wash with Wash Buffer (350 μl per well) and allow to soak for 1-2 min. Remove the liquid by inverting and tapping the plate on to absorbent paper.
- Block the plate with Blocking Buffer (200 μl per well) at 37 °C for 1.5 hours.
- Repeat the aspiration/wash process in Step 2.
- Add 50 μl of standards or sample into the appropriate wells, followed by 50 μl of working biotin-conjugated Competitor. Cover with a plate sealer and incubate at 37 °C for 1 hour.
- Repeat the aspiration/wash process in Step 2.
- Add appropriately diluted Streptavidin HRP (100 μl per well). Cover the plate with a new plate sealer and incubate at 37 °C for 30 min.
- Repeat the aspiration/wash process in Step 2, for a total of 5 times.
- Add Substrate Solution (90 μl per well). Cover the plate with a new plate sealer and incubate at 37 °C for 10-20 min. Keep the plate in the dark and avoid exposure to light.
- Add Stop Solution (50 μl per well). Tap the side of the plate to ensure thorough mixing.
- Measure the absorbance immediately using a microplate reader set at 450 nm.
|
Availability |
Shipped within 5-7 working days. |
Note |
This product is for research use only. |