Product Name
Calpain-10 (CAPN10), ELISA Kit
Full Product Name
Mouse Calpain-10 (CAPN10) ELISA Kit
Product Gene Name
CAPN10 elisa kit
[Similar Products]
Research Use Only
For Research Use Only. Not for use in diagnostic procedures.
Request for Current Manual Insert
Request Current Manual
Samples
Serum, plasma, Cell Culture Supernatants, body fluid and tissue homogenate
Detection Range
0.5-10ng/mL
Preparation and Storage
Store all reagents at 2-8 degree C.
Sample Preparation
We suggest pre-experimenting with neat (undiluted) samples, 1:2 or 1:4 dilutions. Please avoid diluting your samples more than 1:10 as it would exceed the dilution limit set for this kit. If the expected concentration of the target is beyond the detection range of the kit, please contact our technical support team
Product Note
Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual.
Other Notes
Small volumes of CAPN10 elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.
Searchable Terms for CAPN10 purchase
MBS7211013 is a ready-to-use microwell, strip plate ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the Calpain-10 (CAPN10) ELISA Kit target analytes in
biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range in biological research samples containing CAPN10. The ELISA analytical biochemical technique of the MBS7211013 kit is based on CAPN10 antibody-CAPN10 antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect CAPN10 antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, CAPN10. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%).
NCBI/Uniprot data below describe general gene information for CAPN10. It may not necessarily be applicable to this product.
NCBI Accession #
NP_113861.1
[Other Products]
NCBI GenBank Nucleotide #
NM_031673.2
[Other Products]
UniProt Related Accession #
Q9ES66[Other Products]
Molecular Weight
74,527 Da
NCBI Official Full Name
calpain-10
NCBI Official Synonym Full Names
calpain 10
NCBI Official Symbol
Capn10??[Similar Products]
NCBI Protein Information
calpain-10; CANP 10; calcium-activated neutral proteinase 10
UniProt Protein Name
Calpain-10
UniProt Synonym Protein Names
Calcium-activated neutral proteinase 10; CANP 10
UniProt Gene Name
Capn10??[Similar Products]
UniProt Synonym Gene Names
CANP 10??[Similar Products]
UniProt Entry Name
CAN10_RAT
NCBI Summary for CAPN10
large subunit of calpain, a calcium-dependent cysteine protease; human homolog has been associated with type II diabetes mellitus [RGD, Feb 2006]
UniProt Comments for CAPN10
Calcium-regulated non-lysosomal thiol-protease which catalyze limited proteolysis of substrates involved in cytoskeletal remodeling and signal transduction. May play a role in insulin-stimulated glucose uptake ().
Research Articles on CAPN10
1. diabetes-induced renal mitochondrial dysfunction and renal injury may directly result from the loss of renal calpain 10
Precautions
All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.
Disclaimer
While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.
It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.